LS3408 MANUAL PDF

this manual may be trademarks or registered trademarks of their respective companies and are. View and Download Symbol LS quick start manual online. LS Scanner pdf manual download. Also for: Ds View and Download Motorola LSFZ product reference manual online . User Manual. LSFZ Barcode Reader pdf manual download.

Author: Zulkir Dihn
Country: Mexico
Language: English (Spanish)
Genre: Career
Published (Last): 25 November 2015
Pages: 244
PDF File Size: 16.90 Mb
ePub File Size: 10.83 Mb
ISBN: 143-8-46593-885-6
Downloads: 7475
Price: Free* [*Free Regsitration Required]
Uploader: Vudoran

It is broadcast by the cellular device when accessing the cellular system.

LSER Rugged Barcode Scanner Support & Downloads | Zebra

This mode of operation adds bar code reading functionality to a system designed for manual keyboard input. Connect the power supply to the serial connector end of the RS interface cable. Enabling this strips the leading ” from bar codes beginning with two or more zeros but not six zeros, and reports the bar code as UPC-A.

A binary bar code symbology representing each character by a group of five bars, two of which are wide. Ignore Unknown Characters The scanner sounds no error beeps. Security Level 2 Security Level 3 If you selected Security Level 2, and the scanner still misdecodes, select this security level.

Clsi Editing, Notis Editing Symbologies 12 – 39 CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a character Codabar symbol. The unique account number associated with a cellular device. Three options are given for transmitting UPC-A preamble to the host device: Scan a bar code below to select which set a rule belongs to.

The scanner translates the bar code data into keystrokes. Page Option Value Option Check digits are sent. Advanced Data Formatting Int The most general rule should be programmed last. Don’t show me this message again. To change any option, scan the appropriate bar code s provided in the Keyboard Wedge Host Parameters section beginning on page Page Programming Reference B – Page 4 and 12 characters, first scan Code 93 – Length Within Range. Chapter 3 Maintenance and Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions pinouts.

  BAIXAR LIVRO O PAGADOR DE PROMESSAS PDF

The definition of the Graphic User Interface key depends on the attached system This manual also for: For example, to set an aim duration of 0. The laser scanning beam stays on until the laser-on timeout occurs or a decode occurs. Scanner Emulation Interface 10 – 7 Convert All Bar Codes to Code 39 Scan the appropriate bar code below to enable or disable the conversion of all bar code data to Code The Code bar codes have the following format The scanner is shipped with the settings shown in the Symbology Default Table on page also see Appendix In addition to these bar codes for data formatting, see each host chapter for the appropriate host connections and host device features for the scanner.

Page 10 Beep Style It is a standard data transmission code in the U. Select the redundancy level appropriate for the bar code quality. User Preferences 4 – 7 Aim Duration When the scanner is in Level trigger mode default modeAim Duration sets the amount of time the aiming dot is seen before turning into a scanning beam. This ensures compatibility between bar coded data and the host application; the scanner is programmed rather than modifying the host software.

Trioptic Code 39 symbols always contain six characters. By default, a space replaces any characters that do not have a corresponding character in the Code 39 symbology set.

No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Motorola. Baud Rate Baud rate is the number of bits of data transmitted per second.

  LIBRO PRACTIQUEMOS CONTABILIDAD PDF

Upon successful decode, the scanner beeps and the LED turns green.

Symbol Technologies LS 3408 Scanner User Manual

A dirty window can affect scanning accuracy. Enable this feature if the host system requires this data format. The scanner and connected decoder both process the parameter.

This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. Ensure all connections are secure. A versatile and widely used alphanumeric bar code symbology with a set of 43 character types, including all uppercase letters, numerals from 0 to 9 and 7 special characters.

In order to accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid EAN check digit. If you created three rules, the list is configured as follows Chapter 13 Miscellaneous Scanner Options Chapter 13 Miscellaneous Scanner Options Introduction This chapter includes features frequently used to customize how data transmits to the host device.

Page Programming Reference B – 3 The modifier character is the sum of the applicable option values based on Table B Scan the bar codes for all code types desired before selecting other criteria. This may present a problem for customers with older systems that do not recognize some newer symbologies for example, RSS.

Use this mode when you need Scanner Emulation communication. Chapter 10 Scanner Emulation Interface Introduction This chapter provides Scanner Emulation host information for setting up the scanner.

To change any option, scan the appropriate bar code s provided in the Miscellaneous Scanner Parameters section beginning on page