Buy Gefran PID Temperature Controller, 48 x 48 (1/16 DIN)mm, 2 Output Relay, Gefran. Main Product. Technical Reference. User’s manual GEFRAN Buy Gefran PID Temperature Controller, 48 x 48 (1/16 DIN)mm, 2 Output Logic, Gefran series of Microprocessor Controllers support thermocouple. CONTROLLER USER’S MANUAL SOFTWARE VERSION x code L / Edition 15 – 07/ 1 • INSTALLATION Display Keys Accuracy • Dimensions.

Author: JoJocage Melrajas
Country: Estonia
Language: English (Spanish)
Genre: Sex
Published (Last): 27 March 2018
Pages: 460
PDF File Size: 11.33 Mb
ePub File Size: 19.50 Mb
ISBN: 707-2-27275-768-1
Downloads: 59983
Price: Free* [*Free Regsitration Required]
Uploader: Moogulrajas

Page 13 If the Integral Time value is too long Weak integral actiondeviation between the controlled variable and the setpoint may persist. When finished, the Stun code is automatically cancelled.

Gefran 600 User Manual: User’s Manual

Do not clean the case with hydrocarbon-based solvents Petrol, Trichlorethylene, etc. Command from clean contact of 24 V. You should be able to check the correct operation of such units during normal operation of the device. By pressing ‘print’ button you will print only current page. It will be similar to that in the figure: The maunal setpoint reaches the set value at the speed defined by the gradient.

Ambient probe Cap material: A PC programming kit is available for even simpler manal, composed of a cable and a guided program for Windows environment see data sheet code Minimum limit auxiliary l5. You can select between setpoint 1 and setpoint 2 with the faceplate key or with digital input. If an oscillation persists, increase the proportional band.

  FAIR GEYER OKUN PDF

Set the setpoint to the required value 2. PL hotc. To print the manual completely, please, download it. Suitable for piloting AC loads up to a maximum of V a. Amnual Set the proportional band at 0. This function can be assigned manuwl a digital input d. Cut power to the device before accessing internal parts. A second auxiliary analog input from the current transformer is also available.

User’s Manual – Gefran User Manual [Page 18]

Also See for User manual – 31 pages. Manula band Peak P. EMC conformity has been tested with the following connections. Sie eignet sich zum Steuern von ohmschen Lasten bis maximal 5A bei V a.

It can be one of two types: Normally used to retransmit the probe value. The calculated parameters are saved. It is placed near the power supply circuit and near high-voltage relay contacts.

Resistors must be at least 2W ; fit a 1N diode in parallel with the coil of inductive loads that operate in DC. Commande par contact propre ou tension 24 V. A single switch can control several units. Function of digital input 0 1 2 3 4 5 6 7 dig. Normally used to retransmit the probe value. The controller resumes with the parameters programmed before auto-tuning was enabled. Up to 3 alarm functions assignable to an output. Use of these solvents can reduce the mechanical reliability of the device.

  ENCHANTED INC BY SHANNA SWENDSON PDF

Normalmente utilizzata come uscita di regolazione.

GEFRAN USER MANUAL Pdf Download.

The serial communication option available in RS standard allows connection to supervision systems and PLCs with two gefraan The instrument can also select display parameters based on hardware configuration, automatically masking irrelevant parameters.

The warranty excludes defects caused by any Serial interface optional RS, isolated use not conforming to these instructions.

Repairs must be done only by trained and specialized personnel. Page 31 Gefran For correct installation, follow the instructions contained in the manual.

Strom 5A bei V a. Suitable for piloting resistive loads up to a maxi- gefrann of 5A at V a. It’s a community-based project which helps to repair anything.